Power Management ICs

Battery Protection IC for 1-Cell Pack S-82F1B Series

The S-82F1B Series is a protection IC for lithium-ion / lithium polymer rechargeable batteries and includes high-accuracy voltage detection circuits and delay circuits. It is suitable for protecting 1-cell lithium-ion / lithium polymer rechargeable battery packs from overcharge, overdischarge, and overcurrent.
By using an external overcurrent detection resistor, the S-82F1B Series realizes high-accuracy overcurrent protection with less effect from temperature change.

Features

High-accuracy voltage detection circuit
Overcharge detection voltage : 3.500 V to 4.600 V (5 mV step) Accuracy ±15 mV
Overcharge release voltage : 3.100 V to 4.600 V*1 Accuracy ±50 mV
Overdischarge detection voltage : 2.000 V to 3.000 V(10 mV step) Accuracy ±50 mV
Overdischarge release voltage : 2.000 V to 3.400 V*2 Accuracy ±75 mV
Discharge overcurrent detection voltage1 : 0.003 V to 0.100 V (0.5 mV step) Accuracy ±1.5 mV
Discharge overcurrent detection voltage 2 : 0.010 V to 0.100 V (1 mV step) Accuracy ±3 mV
Load short-circuiting detection voltage : 0.020 V to 0.100 V (1 mV step) Accuracy ±5 mV
Charge overcurrent detection voltage : −0.100 V to −0.003 V (0.5 mV step) Accuracy ±1.5 mV
Detection delay times are generated only by an internal circuit (external capacitors are unnecessary).
Discharge overcurrent control function
Release condition of discharge overcurrent status : Load disconnection
Release voltage of discharge overcurrent status : VRIOV = VDD × 0.80 typ.
0 V battery charge function is selectable
Available, unavailable
Power-down function is selectable
Available, unavailable
High-withstand voltage
VM pin and CO pin : Absolute maximum rating 28 V
Wide operation temperature range
Ta = −40°C to +85°C
Low current consumption
During operation : 2.0 μA typ., 4.0 μA max. (Ta = +25°C)
During power-down : 50 nA max. (Ta = +25°C)
During overdischarge : 0.5 μA max. (Ta = +25°C)
Lead-free (Sn 100%), halogen-free

*1. Overcharge release voltage = Overcharge detection voltage − Overcharge hysteresis voltage
(Overcharge hysteresis voltage can be selected as 0 V or from a range of 0.1 V to 0.4 V in 50 mV step.) 

*2. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage can be selected as 0 V or from a range of 0.1 V to 0.7 V in 100 mV step.)

Applications

  • Lithium-ion rechargeable battery pack
  • Lithium polymer rechargeable battery pack

Parts List

  • U(Ux), S and G at the end of the product name of ABLIC Inc. were used to indicate different material specifications as “environmental code”,
    however, these have now been unified into “lead-free and halogen-free” and are identical in terms of environmental quality.
  • Note: Lead-free plating other than 100% Sn is applied to some limited old products, therefore, please contact our sales representatives for details.
  • These descriptions may be different from the actual product name and parameter.
    Please confirm the product name and specifications with the data sheet again.