The S-8255B Series is a monitoring IC for 3-serial to 5-serial cell lithium-ion rechargeable batteries, which includes high-accuracy voltage detection circuits and delay circuits. The S-8255B Series can monitor the status of 3-serial to 5-serial cell lithium-ion rechargeable battery packs.
Connecting an NTC, it allows for the temperature detection at four different points: high temperature detection during charging, low temperature detection during charging, high temperature detection during discharging, and low temperature detection during discharging.
Features
- High-accuracy voltage detection function for each cell
- Overcharge detection voltage n (n = 1 to 5): 3.550 V to 4.600 V (50 mV step) Accuracy ±20 mV
- Overcharge release voltage n (n = 1 to 5): 3.150 V to 4.600 V*1 Accuracy ±50 mV
- Overdischarge detection voltage n (n = 1 to 5): 2.000 V to 3.200 V (100 mV step) Accuracy ±80 mV
- Overdischarge release voltage n (n = 1 to 5): 2.000 V to 3.400 V*2 Accuracy ±100 mV
- Each delay time is settable by external capacitor (Temperature detection delay time is internally fixed)
- Independent control of charge inhibition, discharge inhibition, and power-saving by each control pin
- 0 V battery detection function is selectable
- Available, unavailable
- CO and DO pin output voltage is limited to 8 V max. respectively
- Switching control for 3-serial to 5-serial cell is possible by inputting voltage to the SEL1 pin and the SEL2 pin
- Temperature detection is possible at four different points by connecting an NTC
- High temperature detection ratio during charging / discharging: 0.600 to 0.900 (0.005 step) Accuracy ±0.005
- Low temperature detection ratio during charging / discharging: 0.030 to 0.400 (0.005 step) Accuracy ±0.005
- High-withstand voltage
- Absolute maximum rating 28 V
- Wide operation voltage range
- 5 V to 24 V
- Wide operation temperature range
- Ta = -40°C to +85°C
- Low current consumption
- During operation: 19 μA max. (Ta = +25°C)
- During power-saving: 0.1 μA max. (Ta = +25°C)
- Lead-free, halogen-free
*1. Overcharge release voltage = Overcharge detection voltage - Overcharge hysteresis voltage
(Overcharge hysteresis voltage n (n = 1 to 5) is selectable in 0 V to 0.4 V in 50 mV step)
*2. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage n (n = 1 to 5) is selectable in 0 V to 0.7 V in 100 mV step)
Applications
- Rechargeable lithium-ion battery pack